Siemens 3VA2325-6HN32-0AH0 SENTRON MCCB, 250A, 242kA at 240V

MPN3VA2325-6HN32-0AH0

Siemens SENTRON 3VA2325-6HN32-0AH0, molded case circuit breaker, 3-pole, 250 A continuous, 242 kA interrupting at 240 V, 110 x 138 x 248 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-6HN32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2325-6HN32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-6HN32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-6HN32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-6HN32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2325-6HN32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-6HN32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Product Overview

The Siemens SENTRON 3VA2325-6HN32-0AH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, delivering 250 A continuous current across the full ambient range from -25 °C to 70 °C without derating — that means it holds its full rating even in a hot panel near a drive or transformer. Its interrupting capacity reaches 242 kA at 240 V AC, 187 kA at 415/440 V, 121 kA at 500 V, and 7.5 kA at 690 V — this part is built for high-fault installations where upstream coordination demands extreme SCCR headroom. The breaker includes a trip indicator and comes equipped with 2 auxiliary switches plus 1 trip alarm switch (HQ design), giving the panel builder or PLC direct feedback on breaker state without extra wiring.

Integration & Mounting

The 3VA2 frame measures 110 mm deep, 138 mm wide, and 248 mm high — a standard footprint for this class of MCCB, fitting into existing SENTRON panel layouts and DIN-rail or screw-mount backpanels. Power loss is rated at 37.5 W maximum, which governs ventilation spacing if the breaker is enclosed in a multi-unit lineup.

Frequently asked questions

What are the key ratings of this MCCB?

Continuous current 250 A, 3-pole, with interrupting capacities of 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 7.5 kA at 690 V AC.

Where can I buy the 3VA2325-6HN32-0AH0 and how is it quoted?

It is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA2325-6HN32-0AH0