Siemens 3VA2325-6HN32-0DJ0 SENTRON MCCB, 250 A, 3-pole, 242

MPN3VA2325-6HN32-0DJ0

Siemens SENTRON 3VA2325-6HN32-0DJ0, molded case circuit breaker, 3-pole, 250 A continuous, breaking capacity 242 kA at 240 V, 187 kA at 415 V, line protection design with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-6HN32-0DJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2325-6HN32-0DJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.40 W

Protection & Trip Unit

3VA2325-6HN32-0DJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-6HN32-0DJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-6HN32-0DJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2325-6HN32-0DJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-6HN32-0DJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What the ratings mean for fit

The 3VA2325-6HN32-0DJ0 is a Siemens SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current with no derating across the full 40 °C to 70 °C ambient range — that flat thermal curve means you don't have to oversize for a warm panel, a common headache in enclosed switchgear. The 3-pole design carries breaking capacities of 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V; these are the fault currents it can safely interrupt at each voltage level, so the 415 V figure is the one you'll check against your service entrance or distribution board's available fault current. Line protection design means it's configured for feeder/cable protection, not motor or generator duty — the trip curve and accessories are set for that role.

Built-in accessories and panel integration

This MCCB ships with an undervoltage release (UVR) as the auxiliary release and a complement of 2 auxiliary switches plus 1 trip alarm switch. The UVR will trip the breaker when control voltage drops below its dropout threshold — standard for emergency-stop or undervoltage protection schemes. Dimensions are 248 mm high, 138 mm wide, 110 mm deep; the 110 mm depth is the projection from the mounting surface into the enclosure, so check your gland plate clearance if you're retrofitting into a shallow cabinet. No communication function — this is a standalone thermal-magnetic or electronic-trip MCCB, not a smart breaker with Modbus or PROFINET onboard.

Frequently asked questions

How do I get current pricing and availability for 3VA2325-6HN32-0DJ0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What are the key ratings for this MCCB?

Continuous current is 250 A with no derating from 40 °C to 70 °C ambient. Breaking capacity ranges from 242 kA at 240 V down to 7.5 kA at 690 V. It is a 3-pole line-protection design with an undervoltage release and 2 auxiliary switches plus a trip alarm.

Will 3VA2325-6HN32-0DJ0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?

The 5SQ2370-2YA series are different Siemens catalog numbers; physical fit and terminal layout would need to be verified against the panel's existing cutout and bus connections. The 3VA2325-6HN32-0DJ0 dimensions (248 x 138 x 110 mm) and 3-pole form factor are standard for this class, but a direct drop-in without rewiring cannot be assumed without comparing mounting centers and lug positions.