Skip to main content
Siemens 3VA2325-6HN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-6HN32-0KL0 SENTRON MCCB, 250A, 3-Pole, 242kA

MPN3VA2325-6HN32-0KL0

Siemens SENTRON 3VA2325-6HN32-0KL0, molded case circuit breaker, 250 A, 3-pole, line protection, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-6HN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2325-6HN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-6HN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-6HN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-6HN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2325-6HN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-6HN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers on the line

The Siemens SENTRON 3VA2325-6HN32-0KL0 is a 3-pole molded case circuit breaker rated for 250 A continuous current at 40 °C, with no derating needed up to 70 °C — it holds the full 250 A across the operating temperature range. Interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V — so it handles high available fault current on the secondary side of a distribution transformer without needing a current-limiting fuse upstream. It is designed for line protection (feeder duty) in switchboards and panelboards, with a shunt trip release (STL) and a complement of two auxiliary switches plus one trip alarm and one electrical alarm switch — useful for remote status and trip indication back to a PLC or SCADA.

Dimensions and panel fit

The breaker measures 248 mm high, 138 mm wide, and 110 mm deep — a standard 3-pole MCCB footprint that fits SENTRON distribution panels and most common switchboard cubicle layouts. Power dissipation at rated current is 37.5 W maximum — factor that into enclosure thermal calculations if the panel is tightly packed.

MPN
3VA2325-6HN32-0KL0