Skip to main content
Siemens 3VA2325-7KQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-7KQ32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU8

MPN3VA2325-7KQ32-0AA0
Active

Siemens SENTRON 3VA2325-7KQ32-0AA0, molded case circuit breaker, 3-pole, 250 A, ETU860 electronic trip unit, line protection version, 330 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-7KQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2325-7KQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-7KQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860

Construction & Connection

3VA2325-7KQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-7KQ32-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2325-7KQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-7KQ32-0AA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.8 in
Width (in)5.4 in
Depth (in)4.3 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2325-7KQ32-0AA0 is a 3-pole molded case circuit breaker rated for 250 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its ETU860 electronic trip unit gives you adjustable long-time (tr 0.5–25 s) and short-time (tsd up to 0.5 s) response values, plus ground-fault monitoring via summation current formation on the L-conductor. Breaking capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V — meaning it can interrupt fault currents at the main distribution level, not just downstream subfeeds. The 250 A rating holds flat from 40 °C to 70 °C — no thermal derating curve to calculate, which simplifies panel schedules in warm enclosures. Rated insulation voltage is 800 V, so it's comfortable on 690 V systems with margin. Power loss maxes at 37.5 W; factor that into enclosure ventilation if you're packing multiple breakers in a small cabinet.

Panel fit and integration

Mounts on a standard DIN rail or directly to a backplate. Dimensions: 248 mm high, 138 mm wide, 110 mm deep. The 138 mm width is three pole-spaces wide at roughly 46 mm per pole — standard for this class. Front protection is IP40, so it's fine for enclosed panels but not for washdown zones. Communication function is built in — this variant ships with the ETU860 release that supports connectivity for remote monitoring and trip-data retrieval. Ground-fault monitoring is included as summation current sensing on the L-conductor, which catches leakage without a separate GFCI module.

Frequently asked questions

Does 3VA2325-7KQ32-0AA0 support communication?

Yes, this variant has a communication function built into the ETU860 electronic trip unit, enabling remote monitoring and trip-data retrieval.

MPN
3VA2325-7KQ32-0AA0