Siemens 3VA2325-7KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-7KQ42-0AA0 SENTRON MCCB, 250 A, 4-Pole, 330

MPN3VA2325-7KQ42-0AA0
Active

Siemens SENTRON 3VA2 series, Molded case circuit breaker, 3VA2325-7KQ42-0AA0, 4-pole, 250 A, 330 kA at 240 V, ETU860 release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-7KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2325-7KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-7KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860

Construction & Connection

3VA2325-7KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-7KQ42-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2325-7KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-7KQ42-0AA0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.8 in
Width (in)7.2 in
Depth (in)4.3 in

Product details

What this MCCB carries — and what that means for your panel

The Siemens 3VA2325-7KQ42-0AA0 is a SENTRON 3VA2 molded case circuit breaker, 4-pole, rated 250 A continuous current with a flat thermal derating curve from 40 °C through 70 °C — meaning you don't lose ampacity as the panel warms up, a real advantage in a crowded enclosure. Breaking capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V. That 330 kA at 240 V is the headline number — it clears a massive fault without cascading upstream, sized for the main incoming breaker position in a high-fault industrial distribution board. The ETU860 electronic trip unit gives you adjustable long-time, short-time, instantaneous, and ground-fault protection, with N-conductor protection adjustable from OFF through 20% to 160%. Ground-fault monitoring uses summation current formation on L+N, so it catches leakage without an external CT. Communication function is built in — this breaker talks to the control system, so you get remote trip indication and load monitoring without an add-on module. Mechanical endurance is rated at 20 000 operations, and maximum power loss is 37.5 W — the heat it dumps into the panel is manageable, but factor it into your thermal budget if the enclosure is sealed.

Mounting and integration

Footprint is 248 mm high, 184 mm wide, 110 mm deep — a 4-pole frame that bolts into a standard MCCB mounting plate. IP40 on the front means it's protected against solid objects larger than 1 mm, but not sealed against moisture; keep it inside the panel, not on the washdown side of the gland plate. Rated insulation voltage is 800 V, so it's comfortable on 480 V and 600 V class systems with margin. Storage range is -40 °C to 80 °C; operating range -40 °C to 70 °C — the storage limit is the handling limit, not the running limit.

Lifecycle and sourcing reality

If you're replacing a 5SQ2670-2YA63 or similar legacy frame, the 3VA2325-7KQ42-0AA0 is the functional successor — same 250 A, 4-pole class, but with the ETU860 electronic trip and communication built in. The mounting hole pattern and bus-bar spacing are standard for this frame size, but verify the lug kit compatibility if your panel uses an older termination style.

Frequently asked questions

What is the breaking capacity of 3VA2325-7KQ42-0AA0 at 240 V?

330 kA at 240 V, with 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V.

What trip unit does this MCCB use?

The ETU860 electronic trip unit with adjustable long-time, short-time, instantaneous, and ground-fault protection, plus N-conductor protection adjustable from OFF through 20% to 160%.

Does 3VA2325-7KQ42-0AA0 have communication capability?

Yes, communication function is built in — no add-on module required for remote trip indication and load monitoring.

Where can I buy 3VA2325-7KQ42-0AA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA2325-7KQ42-0AA0