Specifications

3VA2325-7MN32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2325-7MN32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.40 W
3VA2325-7MN32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2325-7MN32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2325-7MN32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2325-7MN32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2325-7MN32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens SENTRON 3VA2325-7MN32-0DC0 — 250 A Motor Protection MCCB

The Siemens SENTRON 3VA2325-7MN32-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuously from 40 °C through 70 °C without derating — that flat thermal curve means it holds full ampacity in a warm enclosure where many breakers would need a down-rate. The interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V — these numbers govern selectivity coordination downstream; at 415 V the 242 kA SCCR covers most industrial service-entrance and feeder applications without needing a current-limiting upstream device.

Panel footprint: 138 mm wide, 248 mm tall, 110 mm deep — fits standard SENTRON 3VA mounting plates and busbar systems. The basic switch core is order code 3VA2325-7MN32-0AA0; the -0DC0 suffix adds the factory-fitted undervoltage release and auxiliary switch block, so no field wiring of add-on modules is needed.

Frequently asked questions

What is the interrupting capacity of 3VA2325-7MN32-0DC0 at 415 V?

242 kA at 415 V, which is the same rating as at 440 V. At 240 V it reaches 330 kA, and at 690 V it is 7.5 kA.

Where can I buy 3VA2325-7MN32-0DC0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What does the motor protection design include?

Phase failure detection and an undervoltage release (UVR) are built in, along with two HQ auxiliary switches for remote status indication.

MPN
3VA2325-7MN32-0DC0