Skip to main content
Siemens 3VA2325-7MN32-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-7MN32-0DL0 SENTRON MCCB, 250 A, 3-Pole, Moto

MPN3VA2325-7MN32-0DL0

Siemens SENTRON 3VA2325-7MN32-0DL0, 3-pole molded case circuit breaker, 250 A rated at 40-70°C, motor protection design with undervoltage release and phase failure detection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-7MN32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2325-7MN32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.40 W

Protection & Trip Unit

3VA2325-7MN32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-7MN32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-7MN32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2325-7MN32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-7MN32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB brings to the panel

The Siemens SENTRON 3VA2325-7MN32-0DL0 is a 3-pole molded case circuit breaker rated 250 A continuously across the full 40 °C to 70 °C ambient range — no derating curve to chase when the panel runs hot. It's purpose-built for motor protection, with phase failure detection built in and an undervoltage release (UVR) already fitted as the auxiliary release. The interrupting ratings climb to 330 kA at 240 V and hold at 242 kA through 440 V, then step to 187 kA at 500 V and 7.5 kA at 690 V, so it handles high-fault utility feeds and transformer-secondaries without cascading upstream.

Integration notes for the panel builder

Footprint is 138 mm wide by 248 mm tall by 110 mm deep — standard SENTRON 3VA2 frame size. The auxiliary switch complement is 2 aux switches + 1 trip alarm + 1 electrical alarm (HQ design), and the basic switch order code is 3VA2325-7MN32-0AA0 if you need a bare switch for a different accessory configuration. Max power loss is 40 W, so factor that into enclosure thermal calculations. Operating range is -25 °C to +70 °C; storage can go from -40 °C to +80 °C.

Frequently asked questions

What is the interrupting capacity of this MCCB at different voltages?

At 240 V it interrupts 330 kA; at 415 V and 440 V it handles 242 kA; at 500 V it's rated 187 kA; and at 690 V it interrupts 7.5 kA.

What auxiliary switches and releases come with 3VA2325-7MN32-0DL0?

It ships with 2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch (HQ design), and an undervoltage release (UVR) as the auxiliary release.

How do I get current pricing and availability for 3VA2325-7MN32-0DL0?

Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels.

Will 3VA2325-7MN32-0DL0 drop into a panel specified around 3VA2225-5HN42-0BB0 without rewiring?

The 3VA2325-7MN32-0DL0 is a 250 A motor-protection MCCB with UVR and phase failure detection; the 3VA2225-5HN42-0BB0 is a different rating and accessory configuration. Physical frame size and terminal layout may differ — verify the mounting footprint and wiring diagram against your existing panel layout before substitution.

MPN
3VA2325-7MN32-0DL0