Skip to main content
Siemens 3VA2325-7MN32-0JL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-7MN32-0JL0 SENTRON MCCB, 250 A, 3-Pole, Moto

MPN3VA2325-7MN32-0JL0

Siemens SENTRON 3VA2325-7MN32-0JL0, molded case circuit breaker, 3-pole, 250 A rated continuous current, motor protection version with ETU350M electronic trip unit, breaking capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2325-7MN32-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2325-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2325-7MN32-0JL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C240 A
Current at 60 °C235 A
Current at 65 °C230 A
Current at 70 °C225 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.37.5 W
3VA2325-7MN32-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2325-7MN32-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2325-7MN32-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2325-7MN32-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2325-7MN32-0JL0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

Breaking capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 52.5 kA at 690 V — figures that give the panel designer substantial SCCR headroom for high-fault installations. The frame measures 138 mm wide × 248 mm high × 110 mm deep, fitting the standard SENTRON 3VA mounting footprint. Panel builders should note the 37.5 W maximum power loss when sizing enclosure ventilation.

Trip unit and auxiliary configuration

The ETU350M overcurrent release supports motor protection with adjustable settings. The breaker includes a voltage trigger and a trip indicator for fault status at a glance.

Derating begins at 55 °C (240 A), stepping down to 225 A at 70 °C.

Frequently asked questions

What is the breaking capacity of 3VA2325-7MN32-0JL0 at 240 V?

330 kA at 240 V, with 242 kA at 415 V and 440 V, 187 kA at 500 V, and 52.5 kA at 690 V.

What trip unit does this MCCB use?

The ETU350M electronic overcurrent release, designed for motor protection with phase-failure detection.

Where can I buy 3VA2325-7MN32-0JL0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2325-7MN32-0JL0