Skip to main content
Siemens 3VA2325-8HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-8HN32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU3

MPN3VA2325-8HN32-0AA0
Active

Siemens SENTRON 3VA2325-8HN32-0AA0, molded case circuit breaker, 250 A, 3-pole, ETU350 electronic trip unit, line protection, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-8HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2325-8HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-8HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2325-8HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-8HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2325-8HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-8HN32-0AA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What the ratings mean for your panel

The Siemens 3VA2325-8HN32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C through 70 °C — no derating across that span, which simplifies panel design in warm enclosures. The 3-pole configuration and ETU350 electronic trip unit make it a line-protection device, not a motor-protection or ground-fault variant. Breaking capacity runs 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V — figures that cover most industrial service-entrance and distribution applications. The ETU350 provides adjustable long-time, short-time, and instantaneous pickup settings, plus a ground-fault alarm function (though not a trip version). The front face carries IP40 protection, adequate for enclosed panel mounting; no IP rating on the body means it is not intended for washdown or outdoor exposure.

Panel fit and integration

Dimensions: 248 mm high, 138 mm wide, 110 mm deep. The 138 mm width is standard for a 3-pole MCCB in this frame size, so it fits existing SENTRON 3VA cutouts. Panel builders should account for the 37.5 W maximum power loss at rated current when sizing enclosure ventilation. No undervoltage release or shunt trip is fitted; the motor-drive option is available as an accessory (Product Extension / Optional / Motor Drive: Yes).

Frequently asked questions

What is the breaking capacity of 3VA2325-8HN32-0AA0 at 415 V?

330 kA at 415 V, which matches the rating at 440 V. At 240 V it reaches 440 kA, and at 690 V it is 52.5 kA.

What trip unit does this MCCB use?

The ETU350 electronic trip unit, which supports adjustable long-time, short-time, and instantaneous protection, plus ground-fault alarm.

Where can I buy 3VA2325-8HN32-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA2325-8HN32-0AA0 drop into a panel specified for 3VA2110-8HN32-0AA0 without rewiring?

Both are 3-pole SENTRON MCCBs in the same frame family, so the mounting footprint and bus-bar spacing are identical. The key difference is the continuous current rating: 250 A on the 3VA2325 versus the lower rating of the 3VA2110. Verify the load and upstream protection before swapping.

MPN
3VA2325-8HN32-0AA0