Skip to main content
Siemens 3VA2340-0HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-0HL32-0AA0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-0HL32-0AA0
Active

Siemens SENTRON 3VA2340-0HL32-0AA0, molded case circuit breaker, 3-pole, 400 A continuous, ETU320 electronic trip unit, 440 kA breaking capacity at 415 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-0HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2340-0HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.96 W
3VA2340-0HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-0HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-0HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2340-0HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-0HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

SENTRON 3VA2 MCCB — 400 A, ETU320, 3-Pole

The Siemens 3VA2340-0HL32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C, with a 3-pole configuration and an ETU320 electronic overcurrent release. The 690 V AC rated operating voltage and 800 V rated insulation voltage cover standard low-voltage networks up to 600/690 V class. The ETU320 trip unit is a basic electronic release with adjustable overload and short-circuit settings, but no ground-fault monitoring or communication function. This keeps the breaker straightforward for line-protection duty where you need reliable overcurrent and short-circuit interruption without added complexity. The breaker does not include an undervoltage release, shunt trip, or voltage trigger — those would be field-added accessories if required.

Rated 400 A continuous up to 50 °C ambient. Above that, the breaker derates linearly: 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. Dimensions: 248 mm height, 138 mm width, 110 mm depth.

Breaking Capacity and Fault Interruption

The 440 kA figure at 415 V is exceptionally high — this breaker is designed for installations with very high available fault current, such as near large transformers or in heavy industrial plants. For comparison, many MCCBs in this current class offer 65-100 kA at 480 V; this unit is in a different league for fault duty. The minimum rated current is 600 A and maximum 4 800 A — these refer to the adjustable short-circuit pickup range of the ETU320, not the continuous rating. The continuous rating is fixed at 400 A.

Frequently asked questions

Does the 3VA2340-0HL32-0AA0 include ground-fault protection?

No, this version is without ground-fault monitoring. The ETU320 is a basic electronic trip unit without ground-fault or communication functions.

MPN