Siemens 3VA2340-4HL32-0AA0 SENTRON MCCB, 400 A, 3-Pole, ETU3

MPN3VA2340-4HL32-0AA0

Siemens SENTRON 3VA2340-4HL32-0AA0, molded case circuit breaker, 400 A, 3-pole, ETU320 electronic trip unit, 121 kA breaking at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-4HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2340-4HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-4HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-4HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-4HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2340-4HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-4HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this 400 A MCCB carries

That ETU320 gives you adjustable thermal and magnetic trip curves, which is what you want when coordinating downstream feeders in a distribution panel.

Breaking capacity — where it clears faults

Short-circuit rating hits 121 kA at 240 V, drops to 75.6 kA at 415 V and 440 V, then 52.5 kA at 500 V, and 7.5 kA at 690 V. At 400 V class (415/440 V) the 75.6 kA still covers most industrial service-entrance duty.

That means a panel running hot near the top of its thermal envelope still gets 340 A out of this frame. Dimensions are 248 mm high, 138 mm wide, 110 mm deep — standard SENTRON 3VA2 footprint, so it swaps into an existing 3VA2 panel cutout without reworking the bus bars. IP40 on the front face only; the body is open for heat shedding inside the enclosure.

Frequently asked questions

Where can I buy 3VA2340-4HL32-0AA0 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ and we'll get you a firm number.

What breaking capacity does 3VA2340-4HL32-0AA0 have at 240 V?

121 kA at 240 V, which covers high-fault service-entrance panels in North American 240 V systems.

MPN