Siemens 3VA2340-5HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HL32-0DH0 SENTRON MCCB, 400 A, 3-Pole, 187

MPN3VA2340-5HL32-0DH0

Siemens SENTRON 3VA2340-5HL32-0DH0, molded case circuit breaker, 3-pole, 400 A continuous, breaking capacity 187 kA at 240 VAC, line protection, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-5HL32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2340-5HL32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-5HL32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-5HL32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5HL32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2340-5HL32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5HL32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2340-5HL32-0DH0 is a 3-pole molded case circuit breaker rated for 400 A continuous current (at 40 °C through 50 °C) and designed for line protection.

That's a standard SENTRON 3VA2 frame footprint — it bolts into the same mounting holes as other 3VA2 3-pole breakers in the 400 A class. The 110 mm depth leaves room for rear-connected busbars or a cable-entry gland plate in a 600 mm deep enclosure.

Frequently asked questions

How do I get current pricing and availability for 3VA2340-5HL32-0DH0?

Submit an RFQ — the part is sourced to order through independent distribution, and pricing and lead time are confirmed at quote time.

Will 3VA2340-5HL32-0DH0 drop into a panel specified around 3VA1020-2ED32-0DD0 without rewiring?

No — the 3VA1020-2ED32-0DD0 is a different frame size (100 A class, different mounting footprint). The 3VA2340-5HL32-0DH0 is a 400 A frame; verify the busbar spacing and enclosure cutout before substitution.

What compliance documentation does this brand provide for 3VA2340-5HL32-0DH0?

Siemens SENTRON MCCBs typically carry UL 489, IEC 60947-2, and CE marking. RoHS and REACH declarations are available from Siemens documentation portal. The evidence does not list specific certs for this order code — confirm with the supplier at quote time.