Siemens 3VA2340-5HL32-0KB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HL32-0KB0 Circuit Breaker, 55kA @ 415V, 400

MPN3VA2340-5HL32-0KB0

Siemens 3VA2 IEC frame 400 MCCB, breaking capacity class M, Icu=55kA @ 415V, 3-pole, ETU320 LI trip unit, In=400A, shunt trip left + 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA2 breaker carries

The Siemens 3VA2340-5HL32-0KB0 is a 3-pole IEC frame 400 molded case circuit breaker with a 55 kA interrupting capacity at 415 V AC (breaking capacity class M). It ships with an ETU320 LI trip unit — fixed at 400 A continuous (In) with adjustable overload protection Ir from 160 A to 400 A and short-circuit pickup Ii adjustable 1.5 to 10 × In. That means you can dial the long-time pickup to match the cable or busbar rating without swapping the breaker body. Factory-fitted accessories include a left-side shunt trip rated 208–277 V AC 50/60 Hz and 220–250 V DC, plus two auxiliary switch changeover contacts. The nut keeper kit is also included — a detail that saves time during panel assembly when the breaker is mounted on a busbar stack.

The 55 kA Icu at 415 V places this breaker in the M (medium) breaking capacity class within the 3VA2 frame. For a 400 A feeder in a 415 V system with a prospective fault current up to 55 kA, this breaker clears the fault without upstream devices needing to open — a key selectivity requirement in industrial switchboards. The ETU320 LI trip unit provides electronic long-time and instantaneous protection; it lacks the short-time delay (LSI) of the ETU330, so it is best applied where downstream coordination is handled by the instantaneous pickup setting rather than a deliberate time band.

Wiring the shunt trip coil requires verifying polarity for the DC supply — the coil holds at 220–250 V DC and drops out below the dropout threshold, so a free-wheel diode across the coil is recommended if the drive circuit is inductive.

Frequently asked questions

What is the interrupting capacity of this breaker?

The 3VA2340-5HL32-0KB0 has a rated ultimate breaking capacity Icu of 55 kA at 415 V AC, placing it in breaking capacity class M within the 3VA2 frame.

What trip unit and protection settings does this breaker have?

It is fitted with an ETU320 LI electronic trip unit. The continuous current rating In is 400 A, with adjustable overload protection Ir from 160 A to 400 A and short-circuit pickup Ii adjustable from 1.5 to 10 × In.

What accessories are included with this order code?

Factory-fitted accessories include a left-side shunt trip rated 208–277 V AC 50/60 Hz and 220–250 V DC, two auxiliary switch changeover contacts, and a nut keeper kit for mounting.