Skip to main content
Siemens 3VA2340-5HL32-0KK0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HL32-0KK0 3VA2 IEC Frame 400, 55kA @ 415V,

MPN3VA2340-5HL32-0KK0

Siemens 3VA2 IEC frame 400, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU320 LI, In=400A, overload Ir=160A...400A, short-circuit Ii=1.5...10 x In, shunt trip left 208-277 V AC 50/60 Hz 220-250 V DC, 1 auxiliary switch change.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA2 frame 400 breaker carries

The Siemens 3VA2340-5HL32-0KK0 is a 3-pole IEC molded-case circuit breaker in the 3VA2 series, frame size 400, with breaking capacity class M rated at Icu=55 kA at 415 V AC. It uses an ETU320 electronic trip unit with LI (long-time and instantaneous) protection. The continuous current rating In is 400 A; the long-time pickup Ir is adjustable from 160 A to 400 A, and the instantaneous pickup Ii is adjustable from 1.5 to 10 times In. It includes a left-mounted shunt trip for 208–277 V AC 50/60 Hz or 220–250 V DC, plus one auxiliary switch (changeover contact). A nut keeper kit is also included.

Where this breaker fits in a panel

This is a fixed (non-withdrawable) MCCB designed for DIN-rail or panel-mount installation in a distribution board or motor control center. The 3VA2 frame 400 footprint is standard across the series, so busbar connections and enclosure cutouts are shared with other 3VA2 400 A units. The left-mounted shunt trip and auxiliary switch occupy accessory slots; verify wiring clearance on the left side of the breaker before laying out the gland plate.

Frequently asked questions

What is the interrupting rating of this breaker?

The breaking capacity class M gives Icu = 55 kA at 415 V AC, 3-pole.

What trip unit and adjustments does this breaker have?

It uses an ETU320 electronic trip unit with LI protection. The continuous rating In is 400 A; Ir is adjustable from 160 A to 400 A, and Ii is adjustable from 1.5 to 10 times In.

What accessories are included with this order code?

It includes a left-mounted shunt trip rated 208–277 V AC 50/60 Hz or 220–250 V DC, one auxiliary switch (changeover contact), and a nut keeper kit.

Where can I buy 3VA2340-5HL32-0KK0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2340-5HL32-0KK0