Skip to main content
Siemens 3VA2340-5HL42-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HL42-0BC0 SENTRON MCCB, 400 A, 4-Pole, ETU3

MPN3VA2340-5HL42-0BC0

Siemens SENTRON 3VA2340-5HL42-0BC0, molded case circuit breaker, 4-pole, 400 A, ETU320 electronic release, 187 kA at 240 V, undervoltage release, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-5HL42-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HL42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-5HL42-0BC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.98.5 W
3VA2340-5HL42-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2340-5HL42-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5HL42-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-5HL42-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5HL42-0BC0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm

Product details

Trip unit, auxiliaries, and release options

The 3VA2340-5HL42-0BC0: The ETU320 overcurrent release is the brains — electronic, adjustable, no communication function or phase failure detection on this variant. The integrated auxiliary trip module is order code 3VA9608-0BB11; the supplied basic switch is 3VA2340-5HL42-0AA0. Mechanical endurance is 15,000 operations.

Physical fit and environmental range

Dimensions are 248 mm high, 184 mm wide, 110 mm deep — standard SENTRON 3VA2 footprint for a 400 A frame. No trip indicator on this variant, no voltage trigger. Ground fault monitoring is not fitted. The breaker mounts in a standard distribution panel or switchboard — no DIN-rail clip on this frame size, it bolts in.

Frequently asked questions

What is the interrupting capacity of 3VA2340-5HL42-0BC0 at 415 V?

121 kA at 415 V, which is the typical IEC distribution voltage for this frame size.

What trip unit does this MCCB use?

It uses the ETU320 electronic overcurrent release, configured for line protection.

Does the 3VA2340-5HL42-0BC0 include an undervoltage release?

Yes, it is fitted with an undervoltage release (UVR) as the auxiliary release.

Where can I buy 3VA2340-5HL42-0BC0 and what is the lead time?

It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA2340-5HL42-0BC0