Skip to main content
Siemens 3VA2340-5HL42-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HL42-0KH0 SENTRON MCCB, 400 A, 4-pole, line

MPN3VA2340-5HL42-0KH0

Siemens SENTRON 3VA2340-5HL42-0KH0 molded case circuit breaker, 400 A rated continuous current, 4-pole, line protection, breaking capacity 187 kA at 240 V, 121 kA at 415 V, ETU320 release, 110 mm depth, 184 mm width, 248 mm height.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5HL42-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HL42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2340-5HL42-0KH0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5HL42-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320

Construction & Connection

3VA2340-5HL42-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HL42-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2340-5HL42-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HL42-0KH0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm

Product details

Breaking capacity and thermal derating

The 3VA2340-5HL42-0KH0: Breaking capacity drops from 187 kA at 240 V to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 17 kA at 690 V — the high 240 V figure covers low-voltage utility feeds; the 415 V rating is the one to check for most European industrial mains. Thermal derating begins at 55 °C: 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, 340 A at 70 °C. Up to 50 °C you get the full 400 A.

Auxiliary and trip configuration

Shunt trip (STL) installed as standard — designated 3VA9688-0BL33. Auxiliary contact version carries 2 auxiliary switches plus 1 trip alarm switch (HQ). Trip indicator and voltage trigger are present; no undervoltage release, no ground fault monitoring, no communication function, no phase failure detection. The basic switch variant is 3VA2340-5HL42-0AA0.

Environmental and mechanical

Operating temperature range -25 °C to 70 °C; storage from -40 °C to 80 °C. Latching endurance rated at 15 000 cycles. Maximum power loss 96 W at rated load. Rated insulation voltage Ui 800 V. Dimensions: 110 mm deep, 184 mm wide, 248 mm high — fits standard MCCB panel cutouts.

Frequently asked questions

What is the breaking capacity of 3VA2340-5HL42-0KH0 at 415 V?

At 415 V the breaking capacity is 121 kA. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 17 kA.

What is the thermal derating for 3VA2340-5HL42-0KH0 above 50 °C?

The full 400 A is available up to 50 °C. At 55 °C it derates to 385 A, at 60 °C to 370 A, at 65 °C to 355 A, and at 70 °C to 340 A.

How do I get current pricing and availability for 3VA2340-5HL42-0KH0?

Submit an RFQ — this part is sourced to order through independent distribution. Pricing and stock are confirmed at quote time.

MPN
3VA2340-5HL42-0KH0