Siemens 3VA2340-5HN32-0BH0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2340-5HN32-0BH0 MCCB, 400 A, 187 kA at 240 V

MPN3VA2340-5HN32-0BH0

SENTRON 3VA2 molded case circuit breaker, 3VA2340-5HN32-0BH0, 400 A rated continuous current Iu, 3-pole, line protection, ETU350 electronic trip unit, 187 kA breaking capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5HN32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2340-5HN32-0BH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-5HN32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2340-5HN32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HN32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2340-5HN32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HN32-0BH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

What this MCCB carries and where it fits

The SENTRON 3VA2340-5HN32-0BH0 is a 3-pole molded case circuit breaker rated for 400 A continuous current (Iu) at 40 °C through 50 °C without derating — above that it steps down to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. The ETU350 electronic trip unit handles the overcurrent protection curve; an undervoltage release (UVR) is factory-fitted. Breaking capacity hits 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V — so the 240 V figure is the headline, but the 415 V/440 V rating is what drives most industrial panel coordination studies. Footprint is 138 mm wide by 248 mm tall by 110 mm deep — standard 3-pole MCCB form factor for a 400 A frame. The auxiliary contact configuration ships as 2 auxiliary switches plus 1 trip alarm switch (HQ type). Rated insulation voltage is 800 V, and maximum power loss at rated current is 98.5 W — factor that into enclosure thermal rise calculations.

Integration notes for the panel builder

Mounts on a standard DIN rail or direct panel-mount via the 3VA2 mounting base. The 138 mm width occupies three 45 mm module spaces — verify gland plate cutouts if retrofitting into an existing MCC bucket. The undervoltage release (UVR) is wired separately; confirm control voltage matches the panel's 24 VDC or 110/230 VAC supply before commissioning. The ETU350 trip unit is field-replaceable without removing the breaker from the panel.

Frequently asked questions

How do I get pricing and availability for 3VA2340-5HN32-0BH0?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time — no stock figures or prices are published here.

What are the key ratings of 3VA2340-5HN32-0BH0?

Rated continuous current Iu is 400 A (derated above 50 °C). Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. The ETU350 electronic trip unit manages overcurrent protection. Rated insulation voltage is 800 V.

Does 3VA2340-5HN32-0BH0 include an undervoltage release?

Yes, it ships with a factory-fitted undervoltage release (UVR) as the auxiliary release. The auxiliary contact configuration is 2 auxiliary switches plus 1 trip alarm switch (HQ type).

MPN
3VA2340-5HN32-0BH0