Skip to main content
Siemens 3VA2340-5HN32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HN32-0DC0 SENTRON MCCB, 400 A, 187 kA

MPN3VA2340-5HN32-0DC0

Siemens SENTRON 3VA2340-5HN32-0DC0, 3-pole molded case circuit breaker, 400 A rated continuous current Iu, 187 kA breaking at 240 V, ETU350 electronic trip unit, undervoltage release (UVR), line protection version.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5HN32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2340-5HN32-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-5HN32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2340-5HN32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HN32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2340-5HN32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HN32-0DC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

400 A MCCB, 187 kA interrupt — this one's built for high-fault mains

Siemens SENTRON 3VA2340-5HN32-0DC0 is a 3-pole molded case circuit breaker rated 400 A continuous (Iu) with a 187 kA interrupting capacity at 240 V AC. That breaking figure drops to 121 kA at 415/440 V, 75.6 kA at 500 V, and 17 kA at 690 V — so it's sized for the main incomer where fault currents are brutal, not a downstream feeder. Holds full 400 A from 40 °C through 50 °C ambient. Derating starts at 55 °C (385 A), then 370 A at 60 °C, 355 A at 65 °C, 340 A at 70 °C. That's a shallow curve — the breaker keeps 85 % of rating at the top end, so it's not forcing a upsized frame for a hot panel. Electronic trip unit is the ETU350 — line protection version. No voltage trigger, no phase failure detection, no communication module. Undervoltage release (UVR) is fitted as the auxiliary release, plus 2 HQ auxiliary switches. The basic switch assembly is order code 3VA2340-5HN32-0AA0; the integrated auxiliary trip is 3VA9608-0BB25.

Mounting dimensions and panel fit

Maximum power dissipation at rated load is 98.5 W. That's per breaker — factor into panel thermal budget. Operating temp range -25 °C to +70 °C; storage from -40 °C to +80 °C. Rated insulation voltage Ui is 800 V. Latching endurance is 15 000 operations — not a daily-switching device; it's a protection device that stays closed.

Frequently asked questions

Where can I buy 3VA2340-5HN32-0DC0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this MCCB at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, 17 kA at 690 V.

Does this breaker include an undervoltage release?

Yes — the auxiliary release is an undervoltage release (UVR). It also carries 2 HQ auxiliary switches.

MPN
3VA2340-5HN32-0DC0