Skip to main content
Siemens 3VA2340-5HN32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2340-5HN32-0HL0 MCCB, 400 A, 3-Pole

MPN3VA2340-5HN32-0HL0

Siemens SENTRON 3VA2340-5HN32-0HL0, molded case circuit breaker, 3-pole, 400 A, line protection, with auxiliary switches and shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-5HN32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-5HN32-0HL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-5HN32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-5HN32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5HN32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-5HN32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5HN32-0HL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

It carries interrupting ratings of 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — so it handles high-fault utility feeds and large motor branch circuits without cascading upstream. The 400 A frame means it's sized for main or heavy feeder duty, not sub-feed or lighting panels.

Continuous current holds 400 A from 40 °C through 50 °C, then derates linearly to 340 A at 70 °C — so in a warm enclosure you still have margin, but above 50 °C you lose 15 A per 5 °C step. Maximum power loss is 96 W, which matters for thermal coordination inside a sealed cabinet. That means it reports status and can be remotely tripped without adding external relays.

Frequently asked questions

What is the interrupting rating of 3VA2340-5HN32-0HL0 at 240 V?

187 kA at 240 V, with 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V.

Where can I buy 3VA2340-5HN32-0HL0?

Sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

MPN
3VA2340-5HN32-0HL0