Skip to main content
Siemens 3VA2340-5HN32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HN32-0JA0 SENTRON MCCB, 400 A, 3-Pole, ETU3

MPN3VA2340-5HN32-0JA0

Siemens SENTRON 3VA2340-5HN32-0JA0, 3-pole molded case circuit breaker, 400 A rated at 40-50 °C, ETU350 electronic trip unit, line protection version, 187 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5HN32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HN32-0AA0

Ratings

3VA2340-5HN32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5HN32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2340-5HN32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HN32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-5HN32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HN32-0JA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with ETU350 — what the ratings mean for your panel

The Siemens SENTRON 3VA2340-5HN32-0JA0 is a 3-pole molded case circuit breaker rated for 400 A continuous current from 40 °C through 50 °C, meaning it holds its full nameplate rating without derating across typical panel ambient temps — you don't lose headroom just because the enclosure runs warm. Above 50 °C it derates stepwise: 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C (–). That thermal curve matters when you're packing breakers into a tight switchboard; the 400 A frame gives you a real-world cushion before you need to step up a frame size. Breaking capacity is the headline number for fault coordination: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V (–). That 187 kA at 240 V is a high-interrupting rating — it handles faults on large transformer secondaries or high-capacity busways without needing a current-limiting fuse upstream. The 121 kA at 415 V covers most industrial distribution in North America and Europe on a 400 V class system, giving you full selectivity headroom downstream. The ETU350 electronic trip unit gives adjustable long-time, short-time, and instantaneous pickup settings — it's not a fixed thermal-magnetic, so you can coordinate selectively with downstream breakers on a panel schedule. Line protection version means it's configured for feeder protection, not motor or generator duty. No auxiliary contacts, no undervoltage release, no ground-fault monitoring on this variant — if you need those, you're looking at a different suffix.

Mounting and integration — fits standard 3-pole MCCB footprint

Dimensions are 248 mm high, 138 mm wide, 110 mm deep — that's 9.76 by 5.43 by 4.33 inches. It's a standard SENTRON 3VA frame size; bolt it onto a DIN rail or panel-mount plate in a distribution board. The IP40 front protection means it's fine for indoor panel use but not washdown areas — keep it inside the enclosure. Power loss is 96 W maximum — that's the heat you need to vent in a sealed enclosure. For a panel with several breakers at this frame size, factor that into your thermal calculation; it's not trivial. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C.

Frequently asked questions

Where can I buy 3VA2340-5HN32-0JA0 and how do I get a price?

We source and quote this breaker to order against an RFQ through our independent distribution channels. Submit a request for quote (RFQ) for current pricing and availability — confirmed at quote time, not a stock count on the page.

What is the breaking capacity of 3VA2340-5HN32-0JA0 at 240 V?

It's rated 187 kA at 240 V — a high-interrupting capacity that handles faults on large transformer secondaries or high-capacity busways without needing an upstream current-limiting fuse.

What compliance documentation does Siemens provide for 3VA2340-5HN32-0JA0?

As a Siemens SENTRON series MCCB, it carries IEC 60947-2 certification for molded case circuit breakers. RoHS and REACH compliance documentation is available from Siemens' standard product compliance portal. The IP40 front protection rating is per IEC 60529.

Will 3VA2340-5HN32-0JA0 drop into a panel specified around 3VA2163-5HL32-0JB0 without rewiring?

No — the 3VA2340-5HN32-0JA0 is a larger frame size (248 x 138 x 110 mm) with a 400 A rating and ETU350 trip, while the 3VA2163-5HL32-0JB0 is a smaller frame with different dimensions and a lower current rating. The bus bars, mounting holes, and lug positions differ; you'd need a new panel layout and coordination study.

MPN