Siemens 3VA2340-5HN32-0KE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5HN32-0KE0 Circuit Breaker, 400A, 55kA @ 415

MPN3VA2340-5HN32-0KE0

Siemens 3VA2 IEC frame 400, breaking capacity class M, 3-pole, line protection ETU350, LSI, In=400A, overload protection Ir=160A...400A, short-circuit protection Isd=1.5...10 x Ir, Ii=10 x In, nut keeper kit, shunt trip (STL) 220-250V DC / 208-277V AC, 4 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2340-5HN32-0KE0 is a 3-pole molded case circuit breaker (MCCB) from the 3VA2 IEC frame 400 series, rated for line protection with an ETU350 electronic trip unit offering LSI (long-time, short-time, instantaneous) protection.

The continuous current rating In is 400 A, with overload protection (Ir) adjustable from 160 A to 400 A — so the breaker can be set to match the actual load rather than changing the frame. Short-circuit protection (Isd) is adjustable from 1.5 to 10 times Ir, and the instantaneous pickup (Ii) is fixed at 10 times In. For a 400 A feeder, that means Ii trips at 4000 A, clearing hard faults fast. The shunt trip (STL) operates on 220–250 V DC or 208–277 V AC, letting a remote emergency-stop or fire-alarm signal open the breaker without an operator at the panel.

Integration notes

The shunt trip occupies its own internal slot, leaving the auxiliary switch complement intact. Mounts in the standard 3VA2 panel cutout; verify bus-bar drilling pattern for the 400 A frame before assembly.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2340-5HN32-0KE0 has an Icu of 55 kA at 415 V AC, which is breaking capacity class M on the 3VA2 frame.

What trip unit does this breaker use?

It uses an ETU350 electronic trip unit with LSI protection: long-time, short-time, and instantaneous settings for line protection.

What is the shunt trip voltage range?

The shunt trip (STL) operates on 220–250 V DC or 208–277 V AC, allowing remote tripping from a safety circuit or fire-alarm panel.

Where can I buy 3VA2340-5HN32-0KE0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.