Siemens 3VA2340-5HN42-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2340-5HN42-0CA0 MCCB, 400A, 4-Pole, 187kA

MPN3VA2340-5HN42-0CA0

Siemens SENTRON 3VA2340-5HN42-0CA0, molded case circuit breaker, 400 A continuous, 4-pole, line protection, with undervoltage release, breaking capacity 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5HN42-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-5HN42-0AA0

Ratings

3VA2340-5HN42-0CA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-5HN42-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-5HN42-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HN42-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-5HN42-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HN42-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA2340-5HN42-0CA0 is a 4-pole molded case circuit breaker rated 400 A continuous current, designed for line protection in distribution panels. Its 187 kA breaking capacity at 240 V and 121 kA at 415 V give it headroom for high-fault installations like transformer secondaries or large motor control centers. The 400 A rating holds flat from 40 °C up to 50 °C, then derates linearly to 340 A at 70 °C — useful to know if the panel runs hot. This unit ships with an undervoltage release (UVR) fitted, so it drops the load if control voltage falls below the dropout threshold — a common requirement for safety circuits or emergency-stop chains. The basic switch supplied is 3VA2340-5HN42-0AA0; the auxiliary switch design is omitted, meaning no built-in aux contacts on the breaker body. Dimensions are 248 mm high, 184 mm wide, 110 mm deep — a standard 4-pole MCCB footprint for Siemens SENTRON 3VA frames. Panel builders should confirm the mounting hole pattern matches existing busbar or backplate cutouts before committing the BOM.

Breaking capacity by voltage — what it means for selectivity

The 3VA2340-5HN42-0CA0 delivers 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V. The steep drop at 690 V means this breaker is not the right choice for 690 V distribution with high fault current — a higher-rated frame or a fused switch would be needed. At 415 V, 121 kA covers most industrial secondary substations; at 240 V, 187 kA handles virtually any low-voltage fault.

Integration notes for the panel builder

Mounts in a standard distribution panel or MCC bucket. The 4-pole design occupies three phase conductors plus neutral. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Maximum power loss is 98.5 W — factor that into enclosure thermal calculations if the panel is densely packed. No communication function, no ground-fault monitoring module, and no trip indicator on this variant. If remote signaling or ground-fault protection is required, a different 3VA variant or an add-on module would be needed.

Frequently asked questions

What is the breaking capacity of 3VA2340-5HN42-0CA0 at 415 V?

121 kA at 415 V, which is the same rating as at 440 V. At 500 V it drops to 75.6 kA, and at 690 V to 7.5 kA.

Does this MCCB include an undervoltage release?

Yes, it is fitted with an undervoltage release (UVR) as the auxiliary release type. The undervoltage release feature is present on this variant.

Where can I buy 3VA2340-5HN42-0CA0 and how is it quoted?

This MCCB is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation — submit an RFQ for a firm commercial offer.

MPN
3VA2340-5HN42-0CA0