Identification

3VA2340-5HN42-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HN42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2340-5HN42-0JL0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5HN42-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2340-5HN42-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5HN42-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2340-5HN42-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5HN42-0JL0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm

Product details

What this 400 A SENTRON MCCB delivers on the line

The Siemens 3VA2340-5HN42-0JL0 is a 4-pole SENTRON molded case circuit breaker rated for 400 A continuous current at 40 °C, with an ETU350 electronic trip unit. It holds the same 400 A rating through 50 °C, then derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C — so in a warm panel you lose about 15 % of headroom at the top end. Interrupting capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V; that 187 kA at 240 V means it handles the full available fault current on a high-capacity 240 V distribution bus without cascading upstream breakers. This is a line-protection variant — no ground-fault monitoring, no phase-failure detection, no communication module. The auxiliary contact block ships with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ version). A shunt trip (STL) is integrated; there is no undervoltage release. The ETU350 release gives adjustable long-time, short-time, instantaneous, and ground-fault protection curves, so you can coordinate selectivity downstream without swapping the breaker.

Panel fit and integration

The 3VA2340-5HN42-0JL0 measures 248 mm high by 184 mm wide by 110 mm deep — a standard SENTRON 3VA2 frame size. It mounts on a DIN rail or can be screw-fixed to a backplate. The 184 mm width for a 4-pole breaker means you need at least 9 module-widths of DIN rail (at 18 mm per module) plus breathing space on each side for cable bending radius. Maximum power loss is 96 W, so factor that into your enclosure thermal budget — a sealed stainless box will need forced ventilation or derating at the top of the ambient range. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The 15 000 mechanical endurance cycles are typical for a 400 A frame — fine for distribution duty but not for frequent switching under load. The basic switch module is order code 3VA2340-5HN42-0AA0; the integrated auxiliary trip is 3VA9688-0BL32. If you need to swap the trip unit or add auxiliary contacts later, those are the service parts to order.

Frequently asked questions

Where can I buy the 3VA2340-5HN42-0JL0 and get a price?

The 3VA2340-5HN42-0JL0 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send your quantity and target lead time for a firm offer.

What is the interrupting capacity of the 3VA2340-5HN42-0JL0 at different voltages?

The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. The 187 kA at 240 V is the highest rating — suitable for high-fault distribution boards.

What is the rated continuous current of the 3VA2340-5HN42-0JL0 and how does it derate with temperature?

The rated continuous current is 400 A at 40 °C, 45 °C, and 50 °C. It derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. Plan for about a 15 % reduction if the panel ambient reaches 70 °C.

What auxiliary contacts come with the 3VA2340-5HN42-0JL0?

The breaker ships with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ version). There is also an integrated shunt trip (STL) release. No undervoltage release is fitted.