Skip to main content
Siemens 3VA2340-5JP32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5JP32-0AB0 SENTRON MCCB, 400 A, 187 kA at 24

MPN3VA2340-5JP32-0AB0

Siemens SENTRON 3VA2340-5JP32-0AB0, molded case circuit breaker, 3-pole, 400 A, ETU550 electronic trip unit, 187 kA at 240 V, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-5JP32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2340-5JP32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-5JP32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2340-5JP32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5JP32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-5JP32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5JP32-0AB0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2340-5JP32-0AB0 is a 3-pole molded case circuit breaker rated 400 A continuous at 40 °C, with an ETU550 electronic trip unit for line protection. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 500 V — enough for high-fault industrial panels where selectivity with upstream gear matters. The ETU550 trip unit gives you adjustable thermal-magnetic or electronic curves, plus a communication function for remote monitoring — handy when you're coordinating with a BMS or PLC. The auxiliary contact version packs 2 auxiliary switches HP, so you can signal breaker status without extra relays. Thermal derating is linear: still 400 A at 50 °C, drops to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. That's typical for a high-current MCCB — plan your panel ambient if you're pushing the full rating.

No DIN rail; it's bolt-on or plug-in base, typical for SENTRON 3VA frames.

Frequently asked questions

What is 3VA2340-5JP32-0AB0's listed depth?

The depth is 110 mm (4.33 in).

What is 3VA2340-5JP32-0AB0's listed width?

The width is 138 mm (5.43 in).

MPN
3VA2340-5JP32-0AB0