Skip to main content
Siemens 3VA2340-5JP32-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5JP32-0HA0 SENTRON MCCB, 400 A, 3-Pole, 187

MPN3VA2340-5JP32-0HA0

Siemens SENTRON 3VA2340-5JP32-0HA0, molded case circuit breaker, 3-pole, 400 A, 187 kA at 240 V, line protection with shunt trip release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5JP32-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-5JP32-0AA0

Ratings

3VA2340-5JP32-0HA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5JP32-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-5JP32-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5JP32-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-5JP32-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5JP32-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB is and what it carries

The Siemens SENTRON 3VA2340-5JP32-0HA0 is a 3-pole molded case circuit breaker rated for 400 A continuous current at 40 °C, designed for line protection in distribution panels. It carries a 187 kA interrupting capacity at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — that SCCR headroom means it handles high-fault utility feeds without cascading upstream. The breaker includes a shunt trip release (STL) for remote emergency-off or undervoltage control, and it supports communication functions for integration into a monitored power system.

Thermal derating and panel fit

The 400 A rating holds flat from 40 °C through 50 °C, then derates to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. If the panel ambient runs above 50 °C, size the feeder and downstream gear for the derated value. The case measures 248 mm high by 138 mm wide by 110 mm deep — that 138 mm width is a standard 3-pole MCCB footprint for a 400 A frame, so it drops into existing SENTRON mounting bases without re-drilling the backplate.

Frequently asked questions

Who supplies 3VA2340-5JP32-0HA0 and how is it quoted for volume purchases?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What is the interrupting capacity of this MCCB at 240 V?

It is rated 187 kA at 240 V, stepping down to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V.

MPN
3VA2340-5JP32-0HA0