Skip to main content
Siemens 3VA2340-5JQ32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5JQ32-0AJ0 SENTRON MCCB, 400 A, ETU560, 187

MPN3VA2340-5JQ32-0AJ0

Siemens SENTRON 3VA2 series, molded case circuit breaker 3VA2340-5JQ32-0AJ0, 400 A, 3-pole, ETU560 electronic trip unit, line protection, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-5JQ32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2340-5JQ32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.96 W
3VA2340-5JQ32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
3VA2340-5JQ32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5JQ32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2340-5JQ32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5JQ32-0AJ0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

400 A MCCB with ETU560 — selectivity and coordination anchor

The Siemens SENTRON 3VA2340-5JQ32-0AJ0 is a 3-pole molded case circuit breaker rated 400 A continuous current, carrying the full 400 A from 40 °C up through 50 °C before the thermal derating curve starts — at 55 °C it holds 375 A, at 60 °C 350 A, and at 70 °C 300 A. That means for a panel designed around a 400 A bus, you get full rating without oversized enclosure ventilation up to 50 °C ambient. Breaking capacity peaks at 187 kA at 240 V, drops to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and 17 kA at 690 V.

If you're replacing an older 3VA2 frame, verify the auxiliary contact wiring scheme matches your existing control circuit.

Integration and panel fit

Dimensions are 248 mm height, 138 mm width, 110 mm depth. The 138 mm width means it occupies three 45 mm pole spaces on the DIN rail or mounting plate. The ground fault monitoring uses summation current formation on the L-conductor — that's a residual-current measurement method that detects ground faults by summing the phase currents, not by a separate toroid on the neutral. This matters if your system is a 3-wire delta without a neutral conductor.

Maximum power loss is 96 W at full rated current. That's the heat you need to extract from the enclosure — for a panel with multiple breakers at 400 A, the cumulative heat load drives the ventilation or air-conditioning sizing. The derating curve above 50 °C is the practical limit: if your panel ambient hits 70 °C, you can only load this breaker to 300 A. The storage range is wider — that's the limit for warehousing or shipping without climate control, not for running.

Frequently asked questions

What is the breaking capacity of 3VA2340-5JQ32-0AJ0 at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. The 187 kA rating at 240 V makes it suitable for high-fault panelboard applications where available fault current is extreme.

What does the ETU560 trip unit do on this MCCB?

The ETU560 is an electronic trip unit with adjustable long-time, short-time, instantaneous, and ground-fault protection curves. It supports zone-selective interlocking for coordination with downstream breakers, allowing you to keep critical feeders alive during branch faults.

Where can I buy 3VA2340-5JQ32-0AJ0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your required quantity and delivery window.

MPN
3VA2340-5JQ32-0AJ0