Siemens 3VA2340-5JQ42-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5JQ42-0KH0 SENTRON MCCB, 400 A, 4-Pole, 187

MPN3VA2340-5JQ42-0KH0

Siemens SENTRON 3VA2340-5JQ42-0KH0, molded case circuit breaker, 400 A, 4-pole, line protection version with ETU560 electronic trip unit, 187 kA at 240 V, 121 kA at 415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5JQ42-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5JQ42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2340-5JQ42-0KH0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5JQ42-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560

Construction & Connection

3VA2340-5JQ42-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5JQ42-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2340-5JQ42-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5JQ42-0KH0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm

Product details

400 A MCCB with ETU560 — line protection for high-fault panels

The Siemens SENTRON 3VA2340-5JQ42-0KH0 is a 4-pole molded case circuit breaker rated for 400 A continuous current (Iu) in a line protection version, built around the ETU560 electronic trip unit. This is the version you spec when you need adjustable long-time, short-time, instantaneous, and ground-fault protection curves — not a thermal-magnetic fixed-trip. The 400 A rating holds at 40 °C, 45 °C, and 50 °C; above that it derates to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C, so if your panel ambient runs hot, factor the thermal curve into your BOM margin. Short-circuit breaking capacity is the headline number for this frame: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. That SCCR profile means it handles high-fault utility feeds at low voltage and still clears a 690 V motor-circuit fault without cascading upstream. For a 400 A frame, the 121 kA at 415 V is the spec that usually decides the panel coordination study.

Trip unit, auxiliaries, and communication

The ETU560 electronic trip unit supports communication — it can talk to the higher-level control system via the SENTRON communication bus, so you get remote trip indication, current metering, and parameter adjustment without opening the panel door. The auxiliary contact block ships with 2 auxiliary switches plus 1 trip alarm switch HQ, which covers the feedback signals a PLC typically needs: breaker closed, breaker open, and trip event. A shunt trip release (STL) is integrated for remote emergency-off or undervoltage-initiated tripping. Ground-fault monitoring uses summation current formation on L + N, so it detects leakage without a separate toroid. Rated insulation voltage Ui is 800 V, which matches the 690 V breaking rating — this breaker is insulated for 690 V line-to-line service. Maximum power loss is 96 W, which is the heat you need to vent in the enclosure; for a 400 A frame that is typical and manageable with natural convection in a ventilated panel. Mechanical endurance is 15,000 operations — not a daily-switch duty class, but fine for a distribution feeder that cycles once or twice a month.

Physical fit and environmental limits

Dimensions: 184 mm wide, 248 mm high, 110 mm deep. Operating temperature range is -25 °C to +70 °C; storage range is -40 °C to +80 °C.

Frequently asked questions

What does the ETU560 trip unit support?

The ETU560 is an electronic trip unit with communication function, adjustable long-time, short-time, instantaneous, and ground-fault protection curves. It also supports summation-current ground-fault monitoring on L+N.

What are the physical dimensions of 3VA2340-5JQ42-0KH0?

184 mm wide, 248 mm high, 110 mm deep.

MPN