Siemens 3VA2340-5KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-5KQ42-0AA0 SENTRON MCCB, 400A 4P ETU860

MPN3VA2340-5KQ42-0AA0
Active

Siemens SENTRON 3VA2340-5KQ42-0AA0, molded case circuit breaker, 4-pole, 400 A rated current, ETU860 electronic trip unit, 187 kA breaking capacity at 240 V AC, communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-5KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2340-5KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-5KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor

Construction & Connection

3VA2340-5KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-5KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-5KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-5KQ42-0AA0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

400 A MCCB with ETU860 — selectivity and communication in one frame

The Siemens 3VA2340-5KQ42-0AA0 is a SENTRON molded case circuit breaker rated for 400 A continuous current at 40-50 °C ambient, with a 4-pole configuration and the ETU860 electronic trip unit. The 187 kA breaking capacity at 240 V AC means this breaker can safely interrupt fault currents up to that level without cascading upstream — critical for high-fault panels where selectivity with downstream devices must hold through a bolted fault. The 800 V rated insulation voltage confirms it is suitable for 480 V and 600 V class systems with margin.

Breaking capacity across the voltage range

At 415 V and 440 V the breaker delivers 121 kA; at 500 V it still holds 75.6 kA; at 690 V it drops to 7.5 kA. For a site electrical engineer building a selective coordination study, the 121 kA at 415 V is the figure that governs most industrial main and feeder applications in 400 V class systems — it gives headroom for high-capacity transformer secondaries without needing a current-limiting fuse upstream.

Thermal derating and operating envelope

The 400 A rating holds flat through 50 °C. Above that it derates: 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. For a panel OEM wireman, the flat rating to 50 °C means no derating is needed in most ventilated enclosures — only tightly packed or unventilated panels above that threshold require a current reduction.

ETU860 trip unit and protection features

The ETU860 electronic trip unit provides adjustable N-conductor protection from OFF to 20-100%, ground-fault monitoring via summation current formation on L+N, and a communication function for integration into plant monitoring systems. No undervoltage release or voltage trigger is fitted as standard. The trip indicator is absent — fault status is read through the communication interface or local LEDs on the trip unit.

Mounting and panel integration

Dimensions are 248 mm height, 184 mm width, 110 mm depth. The IP40 front protection means the breaker face is protected against solid objects over 1 mm but not against moisture — mount in a suitable enclosure for wet or washdown environments. Maximum power loss is 96 W, which should be factored into enclosure thermal calculations for tightly packed switchboards.

Frequently asked questions

Where can I buy 3VA2340-5KQ42-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the breaking capacity of 3VA2340-5KQ42-0AA0 at 415 V?

At 415 V AC the breaking capacity is 121 kA. At 240 V it reaches 187 kA, and at 690 V it is 7.5 kA.

What trip unit does the 3VA2340-5KQ42-0AA0 use?

It uses the ETU860 electronic trip unit, which supports adjustable N-conductor protection, ground-fault monitoring via summation current, and communication functions.

MPN
3VA2340-5KQ42-0AA0