Skip to main content
Siemens 3VA2340-6HL32-0CL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL32-0CL0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-6HL32-0CL0

Siemens SENTRON 3VA2340-6HL32-0CL0, molded case circuit breaker, 3-pole, 400 A, line protection, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6HL32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-6HL32-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-6HL32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6HL32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6HL32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-6HL32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6HL32-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with high interrupting capacity for line protection

The Siemens SENTRON 3VA2340-6HL32-0CL0 is a 3-pole molded case circuit breaker rated for 400 A continuous current, designed for line protection in distribution panels. Its interrupting capacity hits 242 kA at 240 V and 187 kA at 415 V — enough to handle high-fault scenarios without cascading upstream. The 400 A rating holds flat from 40 °C to 50 °C, then derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C, so plan your enclosure ventilation if the ambient climbs above 50 °C.

Panel fit and auxiliary configuration

Dimensions are 110 mm deep, 138 mm wide, 248 mm tall — standard MCCB footprint that fits most DIN-rail or panel-mount enclosures without surprises. Ships with an undervoltage release (UVR) and a full auxiliary switch block: 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch HQ. That covers remote status and trip indication without adding external relays.

Frequently asked questions

How do I get current pricing and availability for 3VA2340-6HL32-0CL0?

Pricing and stock levels are confirmed at quote time. Submit an RFQ through this listing and we'll source it through our independent distribution channels — no minimums, no commitment to buy until you see the numbers.

What is 3VA2340-6HL32-0CL0's listed depth (110 mm) on this component line?

The depth is 110 mm (4.33 in). Combined with a width of 138 mm (5.43 in) and height of 248 mm (9.76 in), it fits standard MCCB panel cutouts and DIN-rail adapters.

MPN
3VA2340-6HL32-0CL0