Skip to main content
Siemens 3VA2340-6HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL32-0DA0 MCCB, 400 A, 242 kA at 240 V

MPN3VA2340-6HL32-0DA0

Siemens SENTRON 3VA2340-6HL32-0DA0, 3-pole molded case circuit breaker, 400 A continuous, 242 kA breaking at 240 V, undervoltage release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HL32-0AA0
3VA2340-6HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-6HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2340-6HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6HL32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2340-6HL32-0DA0 is a 3-pole molded case circuit breaker rated for 400 A continuous current at 40 °C, with a maximum breaking capacity of 242 kA at 240 V and 187 kA at 415 V. At 690 V the breaking capacity drops to 7.5 kA, so keep that in mind if your line runs at higher voltage. The continuous current holds flat at 400 A from 40 °C through 50 °C, then derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. This is a straight line-protection breaker, not a multifunction unit.

The 110 mm depth means it clears shallow backpanels without a gland-plate extension. No DIN-rail mount; this is a bolt-on frame for fixed or draw-out chassis. Power loss at full rated current is 98.5 W — account for that in enclosure thermal calculations, especially if the panel is sealed or has limited ventilation.

Frequently asked questions

Where can I buy 3VA2340-6HL32-0DA0?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a binding price and lead time.

What is the breaking capacity of 3VA2340-6HL32-0DA0 at different voltages?

At 240 V it breaks 242 kA; at 415 V and 440 V it breaks 187 kA; at 500 V it breaks 121 kA; at 690 V it breaks 7.5 kA. The 242 kA at 240 V is the highest figure — suitable for high-fault applications.

Does 3VA2340-6HL32-0DA0 have an undervoltage release?

Yes, it includes an undervoltage release (UVR) for coordinated shutdown on voltage loss. No auxiliary switch or ground-fault monitoring is fitted.

MPN
3VA2340-6HL32-0DA0