Skip to main content
Siemens 3VA2340-6HL32-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL32-0HA0 SENTRON MCCB, 400 A, 3-Pole, Line

MPN3VA2340-6HL32-0HA0

Siemens SENTRON 3VA2340-6HL32-0HA0, molded case circuit breaker, 3-pole, 400 A, line protection, shunt trip release, 242 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6HL32-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HL32-0AA0

Ratings

3VA2340-6HL32-0HA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-6HL32-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-6HL32-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6HL32-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-6HL32-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6HL32-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers

The Siemens 3VA2340-6HL32-0HA0 is a SENTRON molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C, with a maximum breaking capacity of 242 kA at 240 V and 187 kA at 415 V. Designed for line protection in distribution panels, it carries a shunt trip release for remote tripping and is built on a 3-pole frame.

Breaking capacity and derating

This MCCB's interrupting capacity scales with voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. The continuous current holds at 400 A up to 50 °C, then derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. That thermal curve matters for panels with high ambient — if your enclosure runs above 50 °C, you need to account for the reduced ampacity.

Panel fit and dimensions

The breaker measures 248 mm high, 138 mm wide, and 110 mm deep. It mounts on a DIN rail or directly to a panel backplate. The shunt trip release (STL) is integrated for remote tripping; no auxiliary switch or ground-fault monitoring is fitted on this variant.

Frequently asked questions

Where can I buy 3VA2340-6HL32-0HA0?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the continuous current rating of this MCCB?

It is rated for 400 A continuous at 40 °C, holding that value up to 50 °C before derating.

What is the breaking capacity at 415 V?

The interrupting capacity is 187 kA at 415 V.

Does this MCCB include a shunt trip?

Yes, the design includes a shunt trip (STL) release for remote tripping.

MPN
3VA2340-6HL32-0HA0