Siemens 3VA2340-6HL32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL32-0KA0 SENTRON MCCB, 400 A, 3-Pole, Shun

MPN3VA2340-6HL32-0KA0

Siemens SENTRON 3VA2340-6HL32-0KA0, molded case circuit breaker, 3-pole, 400 A continuous rating, line protection design, shunt trip release, adjustable trip range 600–4000 A.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6HL32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HL32-0AA0
3VA2340-6HL32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-6HL32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6HL32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6HL32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2340-6HL32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6HL32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2340-6HL32-0KA0 is a 3-pole molded case circuit breaker rated for 400 A continuous current at 40 °C, with an adjustable thermal-magnetic trip range spanning 600 A minimum to 4000 A maximum — so it covers feeder and large motor branch protection where the load current sits below 400 A but fault currents can climb. Breaking capacity runs 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 7.5 kA at 690 V; that SCCR headroom means it can sit upstream in a high-fault panel without cascading to the main breaker. The 3VA family sits in the SENTRON molded-case platform, common across IEC and UL panels for distribution and industrial feeder protection.

Thermal derating and panel heat budget

At 55 °C it derates to 385 A, at 60 °C to 370 A, at 65 °C to 355 A, and at 70 °C to 340 A. Maximum power loss is 96 W — that heat has to be considered in the enclosure thermal calculation, especially when multiple breakers are ganged in a sealed panel.

Dimensions are 248 mm height, 138 mm width, 110 mm depth. The 110 mm depth (4.33 in) is within the envelope of most 200 mm deep distribution enclosures, but verify clearance for the shunt trip wiring and any auxiliary accessories that plug into the side slots.

Frequently asked questions

Where can I buy 3VA2340-6HL32-0KA0 and get a price?

This part is sourced to order through independent distribution. Submit an RFQ to confirm current availability and pricing — stock levels and lead time vary and are confirmed at quote time.

What breaking capacity does this MCCB have at 415 V?

187 kA at 415 V, and the same 187 kA at 440 V. At 240 V it reaches 242 kA, at 500 V it drops to 121 kA, and at 690 V it is 7.5 kA.

What is the depth of 3VA2340-6HL32-0KA0?

110 mm (4.33 in). Width is 138 mm (5.43 in), height is 248 mm (9.76 in).

Does this breaker include a shunt trip?

Yes, it is fitted with a shunt trip release (STL) for remote tripping. No undervoltage release, no ground-fault monitoring, and no auxiliary switch are included on this order code.

MPN
3VA2340-6HL32-0KA0