Siemens 3VA2340-6HL32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL32-0KL0 SENTRON MCCB, 400 A, 3-Pole, Line

MPN3VA2340-6HL32-0KL0

Siemens SENTRON 3VA2340-6HL32-0KL0, molded case circuit breaker, 3-pole, 400 A continuous rating (adjustable 600–4000 A), line protection design, with shunt trip release and auxiliary switch configuration.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6HL32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2340-6HL32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-6HL32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-6HL32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6HL32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2340-6HL32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6HL32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with adjustable trip and high interrupting capacity

The Siemens SENTRON 3VA2340-6HL32-0KL0 is a 3-pole molded case circuit breaker rated for 400 A continuous current at 40 °C, with an adjustable overload trip range from 600 A minimum to 4 000 A maximum. It is designed for line protection in distribution panels and switchgear. Interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. At 690 V the rating drops sharply — verify the available fault current at the point of installation before specifying. Current-carrying capability is temperature-dependent: full 400 A up to 50 °C, then derates to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. Panel ambient above 50 °C requires applying the derating curve.

Panel integration and auxiliary wiring

Footprint is 110 mm deep, 138 mm wide, 248 mm tall — mounts on a DIN rail or directly to a backplate. The 3-pole block leaves room for side-mounted auxiliary switches and a shunt trip release (STL) on the right side. Comes with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ configuration). The undervoltage release is not fitted; if undervoltage protection is needed, specify a different variant or add an external relay.

Lifecycle and sourcing

The base switch variant is 3VA2340-6HL32-0AA0; the -0KL0 suffix adds the specific auxiliary switch and shunt trip package. Power loss at rated current is 96 W maximum — factor into enclosure thermal calculations.

Frequently asked questions

How do I get pricing and availability for 3VA2340-6HL32-0KL0?

Submit an RFQ through the storefront. This part is sourced to order through independent distribution; a quote with current price and lead time is confirmed at request time.

What are the key ratings for this MCCB?

Rated 400 A continuous at 40 °C, adjustable trip range 600–4 000 A, 3-pole, interrupting capacity 242 kA at 240 V and 7.5 kA at 690 V. Line protection design with shunt trip release.

What is the depth of the 3VA2340-6HL32-0KL0?

The depth is 110 mm (4.33 in), width 138 mm (5.43 in), height 248 mm (9.76 in).

What auxiliary switches are included?

The breaker ships with 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ configuration). No undervoltage release is fitted; a shunt trip release is included.

MPN