Skip to main content
Siemens 3VA2340-6HL42-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HL42-0AJ0 Circuit Breaker, 400A, 85kA @ 415

MPN3VA2340-6HL42-0AJ0

Siemens 3VA2 IEC frame 400, breaking capacity class H, Icu=85kA @ 415V, 4-pole, line protection ETU320, LI, In=400A, overload protection Ir=160A...400A, short-circuit protection Ii=1.5...10 x In, N conductor protection adjustable (OFF, 50%, 100%), nut keeper kit, 2 auxiliary switches HP, 1 trip alarm switch HP.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker does for your panel

The Siemens 3VA2340-6HL42-0AJ0 is a 4-pole IEC molded-case circuit breaker on the 3VA2 frame, rated 400 A continuous and delivering 85 kA breaking capacity at 415 V (class H). That Icu rating means it can safely interrupt a fault current up to 85 kA without welding contacts or rupturing the case — critical for high-fault installations like large motor control centers or transformer secondaries where available fault current is high. The ETU320 trip unit provides LI protection (long-time and instantaneous) with adjustable overload pickup from 160 A to 400 A and instantaneous pickup from 1.5 to 10 times In, so you can tune coordination with downstream breakers without swapping trip units.

What the ratings mean for fit

The 85 kA Icu at 415 V is the short-circuit breaking capacity — the maximum fault current the breaker can clear once without damage. That is the number that decides whether this breaker holds in a high-fault location; if your available fault current exceeds 85 kA, you need a higher-frame or current-limiting breaker upstream. The adjustable N-conductor protection (OFF, 50%, 100% of phase pickup) lets you protect the neutral on a 4-wire system or leave it unprotected on a 3-wire delta — a detail that matters when the panel feeds mixed loads. The two auxiliary switches and one trip-alarm switch are wired in, so you get remote status and alarm feedback without adding external relays.

Frequently asked questions

Where can I buy 3VA2340-6HL42-0AJ0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for 3VA2340-6HL42-0AJ0?

Rated 400 A continuous, 85 kA breaking capacity at 415 V (class H), 4-pole, with an ETU320 LI trip unit offering adjustable overload (160–400 A) and instantaneous (1.5–10 x In) protection, plus adjustable N-conductor protection.

MPN
3VA2340-6HL42-0AJ0