Skip to main content
Siemens 3VA2340-6HN32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HN32-0AH0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-6HN32-0AH0

Siemens SENTRON 3VA2340-6HN32-0AH0, molded case circuit breaker, 3-pole, 400 A continuous, 242 kA breaking capacity at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6HN32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2340-6HN32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-6HN32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-6HN32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6HN32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2340-6HN32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6HN32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Molded case circuit breaker, 400 A frame, 3-pole

The Siemens SENTRON 3VA2340-6HN32-0AH0 is a 3-pole molded case circuit breaker (MCCB) rated for 400 A continuous current, designed for line protection in distribution panels. It carries a breaking capacity of 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V — the voltage-dependent curve tells you the fault current it can safely interrupt at your system voltage. At 690 V the 7.5 kA rating is the limiting factor; above that level the breaker cannot clear the fault without risk of arc-over, so verify your available fault current at that voltage before specifying.

Thermal derating and power loss

The 400 A rating holds up to 50 °C ambient. Above that it derates linearly: 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. If your panel ambient runs hot — say a sealed enclosure near a furnace line — size the load current against the derated value at your actual ambient, not the nameplate 400 A. Maximum power loss is 96 W, which matters for enclosure thermal calculations when grouping several breakers in a confined space.

Panel fit and auxiliary configuration

Dimensions are 248 mm high, 138 mm wide, 110 mm deep — a standard 3-pole MCCB footprint for panel mounting on a backplate or mounting pan. The breaker ships with 2 auxiliary switches plus 1 trip alarm switch (HQ type), wired for status feedback to a PLC or indication lamp. No undervoltage release, no ground-fault monitoring, no communication module on this variant — it is a straight line-protection breaker with aux contacts for remote status. The supplied basic switch is order code 3VA2340-6HN32-0AA0.

Frequently asked questions

How do I get current pricing and availability for 3VA2340-6HN32-0AH0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels; no published price or live inventory count is carried on this page.

What is the breaking capacity of 3VA2340-6HN32-0AH0 at 415 V?

187 kA at 415 V. The breaker also carries 242 kA at 240 V, 187 kA at 440 V, 121 kA at 500 V, and 7.5 kA at 690 V.

MPN
3VA2340-6HN32-0AH0