Siemens 3VA2340-6HN32-0DA0 — Molded Case Circuit Breakers (MCCB)

3VA2340-6HN32-0DA0 SENTRON MCCB, 400 A, 3-pole, ETU350

MPN3VA2340-6HN32-0DA0

Siemens SENTRON 3VA2340-6HN32-0DA0, molded case circuit breaker, 3-pole, 400 A, ETU350 electronic trip unit, line protection, 242 kA at 240 V, 187 kA at 415 V, 110 mm depth, 138 mm width, 248 mm height.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6HN32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6HN32-0AA0

Ratings

3VA2340-6HN32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-6HN32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2340-6HN32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6HN32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-6HN32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6HN32-0DA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

What it is and what it does

The Siemens SENTRON 3VA2340-6HN32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 400 A continuous current at up to 50 °C, with a 242 kA interrupting capacity at 240 V and 187 kA at 415 V — numbers that tell you this breaker handles high-fault utility feeds or large motor branch circuits without cascading upstream. It uses an ETU350 electronic trip unit, so you get adjustable long-time, short-time, and instantaneous protection curves — not a fixed thermal-magnetic bimetal. That means you can coordinate selectivity downstream without swapping the breaker body. The undervoltage release (UVR) is integrated from the factory, which drops the breaker if control voltage falls below the dropout threshold — common in emergency-stop or undervoltage-protection schemes on conveyor lines or pump skids.

Ratings and what they mean for fit

Rated continuous current Iu is 400 A, and the breaker holds that rating from 40 °C up to 50 °C ambient without derating. At 55 °C it's 385 A, at 60 °C it's 370 A, at 65 °C it's 355 A, and at 70 °C it's 340 A — so if your panel runs hot near the top of the enclosure, you need to account for the drop. Interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V. That 242 kA at 240 V is typical for transformer secondary main breakers in large commercial or industrial services; the 40 kA at 690 V still covers most 690 V motor circuits. Rated insulation voltage Ui is 800 V, so the breaker is rated for 690 V line-to-line systems with margin on the insulation coordination. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Physical fit and panel integration

Dimensions are 110 mm deep, 138 mm wide, 248 mm tall. The 138 mm width is the standard 3-pole MCCB footprint for this class. No auxiliary contact block is included, so if you need a status feedback signal to a PLC or a remote trip indicator, you'll add one separately. The basic switch is order code 3VA2340-6HN32-0AA0, and the integrated auxiliary trip is 3VA9608-0BB25 — both are field-installable accessories. Maximum power loss is 98.5 W at rated current — that's heat that stays inside the enclosure. For a panel with multiple breakers side by side, factor that into your thermal rise calculation to avoid nuisance tripping from ambient buildup.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it has an integrated undervoltage release (UVR) from the factory, designed as part of the auxiliary release.

MPN
3VA2340-6HN32-0DA0