Siemens 3VA2340-6HN32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6HN32-0HC0 SENTRON MCCB, 400 A, 3-Pole, ETU3

MPN3VA2340-6HN32-0HC0

Siemens SENTRON 3VA2340-6HN32-0HC0, molded case circuit breaker, 3-pole, 400 A, ETU350 electronic trip unit, 242 kA interrupting at 240 V, shunt trip, 2 HQ aux switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6HN32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-6HN32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.96 W
3VA2340-6HN32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2340-6HN32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6HN32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-6HN32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6HN32-0HC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

It carries a 242 kA interrupting capacity at 240 V, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V — so it handles high-fault utility feeds and large motor branch circuits without cascading upstream. The thermal derating curve is flat from 40 °C to 50 °C (full 400 A), then steps down: 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. The 110 mm depth and 138 mm width fit standard panel-mount cutouts for this frame size.

Integration and compliance notes

Maximum power loss is 96 W — account for that in enclosure thermal calculations. These are the replacement subassemblies if a service swap is needed.

Frequently asked questions

Where can I buy 3VA2340-6HN32-0HC0?

It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the interrupting capacity of this MCCB?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V.

Does it include an undervoltage release?

No, but it has a shunt trip (STL) for remote opening and two HQ auxiliary switches.

MPN
3VA2340-6HN32-0HC0