Skip to main content
Siemens 3VA2340-6JP32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6JP32-0AC0 SENTRON MCCB, 400 A, 3-Pole, ETU5

MPN3VA2340-6JP32-0AC0

Siemens SENTRON 3VA2340-6JP32-0AC0, molded case circuit breaker, 3-pole, 400 A, ETU550 electronic trip unit, line protection, 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6JP32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-6JP32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.96 W
3VA2340-6JP32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
3VA2340-6JP32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6JP32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-6JP32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6JP32-0AC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The 400 A frame and 3-pole configuration suit main feeder or large motor branch protection in switchboards and distribution panels.

This matters when you need to clear a fault on a branch without taking the whole panel off-line.

Above that, derate linearly: 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. The 138 mm width and 248 mm height fit standard MCCB mounting footprints; depth is 110 mm. IP40 on the front protects against tool entry in a closed panel. Maximum power loss is 96 W — account for this in enclosure thermal calculations, especially in a crowded switchboard.

Frequently asked questions

What is the breaking capacity of 3VA2340-6JP32-0AC0 at 415 V?

187 kA at 415 V, which covers most industrial fault-current levels without requiring upstream current-limiting fuses.

Where can I buy 3VA2340-6JP32-0AC0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Does 3VA2340-6JP32-0AC0 include an undervoltage release?

No, this variant ships without an undervoltage release. The auxiliary release design is listed as 'without auxiliary release'.

MPN
3VA2340-6JP32-0AC0