Skip to main content
Siemens 3VA2340-6JP32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6JP32-0BC0 SENTRON MCCB, 400 A, 3-Pole, 242

MPN3VA2340-6JP32-0BC0

Siemens SENTRON molded case circuit breaker, 3VA2340-6JP32-0BC0, 400 A, 3-pole, line protection, with undervoltage release and communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6JP32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-6JP32-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-6JP32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6JP32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6JP32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-6JP32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6JP32-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

It ships with a basic switch (3VA2340-6JP32-0AA0) as the supplied base unit. Thermal derating is published: the 400 A rating holds from 40 °C up to 50 °C, then drops to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. Plan the enclosure ventilation accordingly if the ambient exceeds 50 °C.

Compared to the smaller 3VA2116-5JP32-0AE0 (a 160 A frame), this 3VA2340 carries a 400 A frame with substantially higher breaking capacity — 242 kA vs the 160 A unit's lower ratings — so a panel originally specified for the 160 A breaker cannot simply drop in the 400 A version without checking busbar ampacity, lug size, and enclosure thermal limits.

Frequently asked questions

What is the breaking capacity of 3VA2340-6JP32-0BC0 at different voltages?

Rated breaking capacity is 242 kA at 240 V, 187 kA at 415 V, 187 kA at 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. These values cover most industrial low-voltage distribution scenarios.

How do I get current pricing and availability for 3VA2340-6JP32-0BC0?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation — figures are confirmed at quote time.

MPN