Skip to main content
Siemens 3VA2340-6JP32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6JP32-0DA0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-6JP32-0DA0

Siemens SENTRON 3VA2 series molded case circuit breaker, 3VA2340-6JP32-0DA0, 3-pole, 400 A rated continuous current, line protection design, with undervoltage release and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6JP32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6JP32-0AA0

Ratings

3VA2340-6JP32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-6JP32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-6JP32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6JP32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-6JP32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6JP32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

3VA2340-6JP32-0DA0 — 400 A SENTRON MCCB with undervoltage release

Breaking capacity varies with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. That 242 kA at 240 V covers high-fault utility feeds; the 7.5 kA at 690 V is the limiting case for industrial 690 VAC networks. The adjustable thermal-magnetic trip unit covers a range from 600 A minimum to 4 000 A maximum, giving selectivity headroom for downstream feeders. Rated continuous current holds at 400 A up to 50 °C ambient; above that it derates linearly to 300 A at 70 °C.

Integration and mounting

Panel footprint: 248 mm high, 138 mm wide, 110 mm deep. The 3-pole form factor mounts on a standard backplate or DIN-rail adapter. An integrated undervoltage release (UVR) is fitted as the auxiliary release — verify coil voltage matches your control circuit before energizing. Communication function is built in, supporting integration with higher-level monitoring or remote trip indication. Maximum power loss is 98.5 W at rated load — account for this in enclosure thermal calculations. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Frequently asked questions

What is the continuous current rating of this MCCB?

400 A continuous, with a thermal-magnetic trip range adjustable from 600 A minimum to 4 000 A maximum.

MPN
3VA2340-6JP32-0DA0