Skip to main content
Siemens 3VA2340-6JP32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6JP32-0KL0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-6JP32-0KL0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2340-6JP32-0KL0, 400 A continuous, 3-pole, line protection, 242 kA breaking capacity at 240 V, active lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6JP32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-6JP32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-6JP32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6JP32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6JP32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-6JP32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6JP32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

It carries a 242 kA breaking capacity at 240 V, stepping down to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V — the SCCR curve tells you where this breaker can clear a fault without upstream coordination issues.

The 400 A rating holds steady up to 50 °C ambient; above that it derates linearly to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. If the panel runs hot, the real ampacity is lower than the nameplate.

Auxiliary and communication options

A communication function is built in — no separate module needed for basic signaling. The base switch is order code 3VA2340-6JP32-0AA0; this -0KL0 suffix adds the auxiliary and alarm contacts and the shunt trip.

Frequently asked questions

Does the 3VA2340-6JP32-0KL0 include a shunt trip?

Yes, it includes a shunt trip release (STL) for remote tripping, plus 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch.

MPN
3VA2340-6JP32-0KL0