3VA2340-6JQ32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2340-6JQ32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-6JQ32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2340-6JQ32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6JQ32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2340-6JQ32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6JQ32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this 400 A SENTRON frame carries

Breaking capacity scales with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V. Current rating holds at 400 A from 40 °C through 50 °C ambient, then derates to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. The 138 mm width is a standard 3-pole MCCB footprint for this frame class — it fits the same DIN-rail or mounting-plate cutout as other SENTRON 3VA breakers in the 400 A range, so a panel laid out for a 3VA2225-5JQ32-0AK0 will accept this unit without re-drilling the gland plate.

What's inside the box — auxiliary and release configuration

Max power loss is 98.5 W at rated load — that's the heat the breaker dumps into the enclosure. For a panel with multiple breakers ganged together, that figure drives the ventilation or derating calculation; don't bury it in a sealed box without accounting for the thermal rise. The basic switch (the bare breaker without accessories) is order code 3VA2340-6JQ32-0AA0 — useful if you're comparing a bare unit against this fully-populated variant to see what the UVR and aux switch package adds to the BOM line.

Environmental and operating range

The 70 °C operating max matches the top end of the derating curve, so the thermal limit is consistent.

Frequently asked questions

How do I get pricing and availability for 3VA2340-6JQ32-0DH0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels — no automated stock figure here, just a real quote against your required quantity and delivery window.

What is the closest functional second-source to 3VA2340-6JQ32-0DH0?

The 3VA2225-5JQ32-0AK0 is the closest peer in the same SENTRON family — same 3-pole form factor, same auxiliary switch configuration (2 aux + 1 trip alarm HQ), and same UVR release. The key difference is frame size: 3VA2225-5JQ32-0AK0 is a 250 A frame, while this 3VA2340-6JQ32-0DH0 is a 400 A frame. Panel cutout dimensions are identical (248 mm H × 138 mm W × 110 mm D), so it drops into the same mounting footprint without rewiring — but the continuous current rating and interrupting capacity will differ. If your load is under 250 A and the fault current is within the 250 A frame's capability,

What is the depth of 3VA2340-6JQ32-0DH0?

Depth is 110 mm (4.33 in).

What is the width of 3VA2340-6JQ32-0DH0?

Width is 138 mm (5.43 in).

Will 3VA2340-6JQ32-0DH0 drop into a panel specified around 3VA2225-5JQ32-0AK0 without rewiring?

Yes — the mounting dimensions are identical (248 mm H × 138 mm W × 110 mm D), so the breaker fits the same cutout and DIN-rail or mounting-plate footprint. The terminal layout and bus-bar connections are the same across the 3VA frame sizes in this family, so no re-drilling or re-bussing is needed. However, the 400 A frame requires conductors sized for 400 A continuous, which may be larger than what the 250 A panel was wired for — check the cable ampacity before assuming a drop-in swap.

MPN