Specifications

Identification

3VA2340-6KP32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2340-6KP32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-6KP32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850

Construction & Connection

3VA2340-6KP32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6KP32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2340-6KP32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6KP32-0AD0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The Siemens SENTRON 3VA2340-6KP32-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C, configured for line protection with an ETU850 electronic trip unit. It carries a breaking capacity of 242 kA at 240 V and 187 kA at 415 V, making it suitable for high-fault-current distribution panels in industrial switchgear.

Ratings and what they mean for the panel

The 400 A rating holds flat from 40 °C to 50 °C, then derates linearly to 300 A at 70 °C. If your enclosure ambient runs above 50 °C, you lose 25 A per 5 °C step — plan the thermal budget accordingly. The 242 kA at 240 V and 187 kA at 415 V tell you this breaker can interrupt a bolted fault at those levels without welding or rupturing, which is critical for high-capacity transformer secondaries or busway feeds. Rated insulation voltage is 800 V, so it's safe for 690 V line-to-line systems common in heavy industrial drives. The ETU850 release provides electronic long-time, short-time, instantaneous, and ground-fault protection curves — adjustable via the front panel or communication interface.

Communication and auxiliary contacts

This MCCB includes a communication function and three auxiliary switches (HQ type) for status feedback to the PLC. No undervoltage release, no voltage trigger, and no ground-fault monitoring are fitted on this variant.

Dimensions and panel fit

The breaker measures 248 mm high, 138 mm wide, and 110 mm deep. Account for handle throw and rear terminals when sizing enclosure depth.

Frequently asked questions

What is 3VA2340-6KP32-0AD0's listed depth?

The depth is 110 mm, excluding handle throw and rear terminal projections.