Skip to main content
Siemens 3VA2340-6KP32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6KP32-0AF0 SENTRON MCCB, 400 A, 3-Pole, Line

MPN3VA2340-6KP32-0AF0

Siemens SENTRON 3VA2340-6KP32-0AF0, molded case circuit breaker, 3-pole, 400 A continuous, adjustable thermal-magnetic trip 600–4000 A, breaking capacity 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-6KP32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2340-6KP32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-6KP32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-6KP32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-6KP32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2340-6KP32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-6KP32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB carries — and where it sits in the panel

The Siemens SENTRON 3VA2340-6KP32-0AF0 is a 3-pole molded case circuit breaker rated for 400 A continuous at 40 °C, with an adjustable trip range from 600 A up to 4000 A — that's a 6.7:1 span that lets you dial in the overload protection without swapping the breaker frame. Breaking capacity hits 242 kA at 240 V, drops to 187 kA at 415 V and 440 V, then 121 kA at 500 V, and 7.5 kA at 690 V. That 242 kA figure at 240 V means it can interrupt a fault current that would vaporize a standard industrial panelboard — this is a high-interrupting-capacity frame sized for transformer secondaries or large motor control centers where available fault current runs high. Thermal derating is published: full 400 A holds through 50 °C, then steps down to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. If your panel ambient runs above 50 °C, the continuous current you can pull is the derated value, not the nameplate — plan your load accordingly. The breaker includes communication and other measurement functions, meaning it can report status and metering data upstream — useful for a plant-floor energy monitoring scheme or a predictive-maintenance dashboard. The auxiliary switch configuration is 1 auxiliary switch plus 1 trip alarm switch HQ, giving you a separate signal for trip events versus normal open/close.

Panel fit and integration

Dimensions: 248 mm height, 138 mm width, 110 mm depth. That 138 mm width is the 3-pole frame footprint — verify your existing busbar spacing and enclosure depth before cutting gland plates. The 110 mm depth means it clears most 200 mm deep enclosures, but check the handle throw arc if you're mounting close to the door. Power loss is 96 W maximum at rated load. That's a non-trivial heat source inside a sealed enclosure — account for it in your thermal calculation, especially if the panel also carries drives or transformers. At 70 °C max operating ambient and -25 °C minimum, the breaker covers most indoor industrial environments; storage range is -40 °C to 80 °C.

Frequently asked questions

What is the breaking capacity of 3VA2340-6KP32-0AF0 at 240 V?

242 kA at 240 V, stepping down to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V.

Where can I buy 3VA2340-6KP32-0AF0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
3VA2340-6KP32-0AF0