Skip to main content
Siemens 3VA2340-6KP32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6KP32-0BC0 SENTRON MCCB, 400 A, 242 kA at 24

MPN3VA2340-6KP32-0BC0

Siemens SENTRON 3VA2340-6KP32-0BC0, molded case circuit breaker, 3-pole, 400 A, ETU850 electronic trip unit, 242 kA interrupting at 240 V, line protection, with undervoltage release and communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6KP32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-6KP32-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.98.5 W
3VA2340-6KP32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2340-6KP32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6KP32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-6KP32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6KP32-0BC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

What this breaker delivers at the bus

The Siemens 3VA2340-6KP32-0BC0 is a 3-pole SENTRON molded case circuit breaker rated for 400 A continuous at 40 °C, with an ETU850 electronic trip unit handling line protection duty. Interrupting capacity hits 242 kA at 240 V, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V — so it clears high-fault scenarios on the secondary side of a distribution transformer or at a large motor control center without cascading upstream. Thermal derating kicks in above 50 °C: still holds 400 A at 50 °C, then 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C. Built-in undervoltage release (UVR) and a communication function let this breaker integrate with a BMS or PLC for remote trip and status monitoring. The auxiliary contact version carries 2 HQ auxiliary switches; the integrated auxiliary trip unit is order code 3VA9608-0BB11. No ground-fault monitoring or phase failure detection on this variant — specify those separately if needed.

Basic switch assembly is order code 3VA2340-6KP32-0AA0; the 3VA2340-6KP32-0BC0 is the fully-assembled MCCB with ETU850 and UVR pre-installed. Insulation voltage (Ui) rated at 800 V.

Frequently asked questions

Does this MCCB include ground-fault monitoring?

No — this variant is specified without ground-fault monitoring. If GF protection is required, a different 3VA2 variant or an external GF relay would be needed.

MPN
3VA2340-6KP32-0BC0