Specifications

3VA2340-6KP32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-6KP32-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-6KP32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-6KP32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6KP32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-6KP32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6KP32-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2340-6KP32-0CL0 is a SENTRON molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C, with a maximum interrupting capacity of 242 kA at 240 V and 187 kA at 415 V. It is a 3-pole, line-protection design with an integrated undervoltage release and communication function, making it suitable for main feeder or large subfeed applications in industrial switchgear.

The 400 A continuous rating holds flat from 40 °C to 50 °C, then derates to 375 A at 55 °C and 300 A at 70 °C — the thermal curve governs real-world ampacity in a closed cabinet. The 242 kA interrupting rating at 240 V confirms fault-clearing capability at the service entrance; at 690 V the rating drops to 7.5 kA, so verify the available fault current at your system voltage. Panel footprint: 248 mm height, 138 mm width, 110 mm depth.

Integration details

The communication function enables integration with higher-level monitoring systems — useful for a semiconductor fab's power distribution monitoring where a single particle event from an unmonitored fault can scrap a wafer lot.

Frequently asked questions

What is the interrupting capacity of 3VA2340-6KP32-0CL0 at different voltages?

The interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V.

Where can I buy 3VA2340-6KP32-0CL0 and how is it quoted?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
3VA2340-6KP32-0CL0