Skip to main content
Siemens 3VA2340-6KP32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-6KP32-0KH0 SENTRON MCCB, 400 A, ETU850

MPN3VA2340-6KP32-0KH0

Siemens SENTRON 3VA2340-6KP32-0KH0, molded case circuit breaker, 3-pole, 400 A (at 40 °C), ETU850 electronic trip unit, 242 kA breaking capacity at 240 V, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-6KP32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2340-6KP32-0KH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C375 A
Current at 60 °C350 A
Current at 65 °C325 A
Current at 70 °C300 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V40 kA
Power loss, max.96 W
3VA2340-6KP32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
3VA2340-6KP32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-6KP32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2340-6KP32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-6KP32-0KH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The 3-pole frame is rated for an insulation voltage Ui of 800 V and delivers breaking capacities from 242 kA at 240 V down to 40 kA at 690 V.

Thermal derating — where the 400 A holds and where it drops

At 55 °C it derates to 375 A, at 60 °C to 350 A, at 65 °C to 325 A, and at 70 °C to 300 A.

Breaking capacity across voltages — selectivity planning

The interrupting ratings span the common industrial voltage bands: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 40 kA at 690 V. For a 480 V distribution panel (common in North America) the relevant figure is the 440 V rating at 187 kA — that is well above typical available fault current for most secondary substations, so you have headroom for selective coordination downstream. At 690 V, the 40 kA rating still covers most industrial motor-control-center faults.

The MCCB measures 248 mm high, 138 mm wide, and 110 mm deep — a 3-pole frame that fits standard Siemens 3VA switchboard and panelboard mounting patterns. Power loss is 96 W maximum, so account for that heat in the enclosure thermal calculation.

Integrated auxiliary and trip options

Communication function and other measurement functions are present — the ETU850 supports Modbus RTU communication for power monitoring and trip data. There is no undervoltage release or phase-failure detection on this specific configuration.

Frequently asked questions

What is 3VA2340-6KP32-0KH0's rated current and how does temperature affect it?

The rated continuous current is 400 A from 40 °C to 50 °C ambient. It derates to 375 A at 55 °C, 350 A at 60 °C, 325 A at 65 °C, and 300 A at 70 °C.

What breaking capacity does this MCCB have at 480 V?

At 440 V (the nearest standard rating to 480 V) it interrupts 187 kA. At 500 V it is rated for 121 kA.

Where can I buy 3VA2340-6KP32-0KH0 and how is it quoted?

This part is sourced through independent industrial-automation distribution. Submit an RFQ for current pricing and availability — quotes are confirmed at the time of request.

What is the physical size of 3VA2340-6KP32-0KH0?

It is 248 mm high, 138 mm wide, and 110 mm deep — a standard 3-pole MCCB frame.

Does this breaker include communication capability?

Yes, the ETU850 trip unit supports communication functions (Modbus RTU) and other measurement functions for power monitoring.

MPN
3VA2340-6KP32-0KH0