Siemens 3VA2340-7HL32-0AB0 MCCB, 400 A, 330 kA at 240 V

MPN3VA2340-7HL32-0AB0

Siemens SENTRON 3VA2, molded case circuit breaker, 3VA2340-7HL32-0AB0, 400 A, 330 kA at 240 V, ETU320, 3-pole, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-7HL32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2340-7HL32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.96 W
3VA2340-7HL32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2340-7HL32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-7HL32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2340-7HL32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-7HL32-0AB0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The breaking capacity hits 330 kA at 240 V AC, tapering to 242 kA at 415/440 V, 187 kA at 500 V, and 52.5 kA at 690 V — numbers that matter when you're coordinating selectivity downstream of a large transformer or feeding a high-fault bus.

Thermal derating and endurance

Mechanical endurance is listed at 15 000 operations — typical for a 400 A frame in distribution duty. The auxiliary contact version ships with two HP auxiliary switches, and there's no undervoltage release or ground-fault module on this variant.

Frequently asked questions

Where can I buy 3VA2340-7HL32-0AB0 and how do I get a price?

This part is available to order through independent distribution. Submit an RFQ for a firm price and lead-time confirmation — availability is confirmed at quote time.

What is the breaking capacity of 3VA2340-7HL32-0AB0 at 415 V?

At 415 V AC the breaking capacity is 242 kA, which matches the 440 V rating and drops to 187 kA at 500 V.

What trip unit does this MCCB use?

It uses the ETU320 electronic trip unit, which supports adjustable overload and short-circuit protection settings for line protection applications.

MPN
3VA2340-7HL32-0AB0