Siemens 3VA2340-7HL32-0AD0 SENTRON MCCB, 400 A, 3-pole, ETU3

MPN3VA2340-7HL32-0AD0

Siemens SENTRON 3VA2340-7HL32-0AD0, molded case circuit breaker, 3-pole, 400 A, ETU320 electronic trip unit, line protection, 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-7HL32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-7HL32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.96 W
3VA2340-7HL32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2340-7HL32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-7HL32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2340-7HL32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-7HL32-0AD0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

It is designed for main or feeder protection in distribution panels where high interrupting capacity is required — 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 52.5 kA at 690 V — giving it a very high SCCR for fault duty up to those levels without cascading upstream.

The breaker carries its full 400 A rating from 40 °C up to 50 °C ambient; above that it derates linearly to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. For a panel with a 50 °C internal ambient, no derating is needed. The 138 mm width, 248 mm height, and 110 mm depth fit standard SENTRON 3VA switchboard mounting footprints — verify gland-plate cutout against the existing panel layout. Maximum power loss is 96 W, which should be factored into enclosure thermal calculations.

Key features for the specifier

Frequently asked questions

What is the breaking capacity of 3VA2340-7HL32-0AD0 at 415 V?

The breaking capacity is 242 kA at 415 V, which is the same rating as at 440 V.

Where can I buy 3VA2340-7HL32-0AD0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN