Specifications

Identification

3VA2340-7HL32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-7HL32-0AA0

Ratings

3VA2340-7HL32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W

Protection & Trip Unit

3VA2340-7HL32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-7HL32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-7HL32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2340-7HL32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-7HL32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA2340-7HL32-0CA0 is a 3-pole molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C ambient, with a thermal derating curve that holds 400 A through 50 °C, then drops to 385 A at 55 °C and 340 A at 70 °C. Breaking capacity runs 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 7.5 kA at 690 V — covering most LV fault-current scenarios downstream of a transformer. An undervoltage release (UVR) is built in; no auxiliary switch or ground-fault module is fitted on this variant.

Panel fit and footprint

At 110 mm deep × 138 mm wide × 248 mm tall, this breaker fits standard SENTRON 3VA mounting bases and busbar systems. The 138 mm width is a 3-pole frame — verify gland-plate cutout if retrofitting into a panel originally laid out for a different MCCB family. Depth is shallow enough for 200 mm-deep enclosures; no rear-access clearance needed beyond the standard 50 mm arc-chute vent gap.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

330 kA at 240 V, derating to 242 kA at 415/440 V, 187 kA at 500 V, and 7.5 kA at 690 V.

Does this breaker include an undervoltage release?

Yes, an undervoltage release (UVR) is included. No auxiliary switch or ground-fault module is fitted on this variant.

Where can I buy 3VA2340-7HL32-0CA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2340-7HL32-0CA0